Skip to content
Skip to product information
Description
Charge
Charge Voltage Range 14.7V @ 25°C (77°F)
Float Voltage Range 13.8V @ 25°C (77°F)
Recommended Charge Current 15 A
Maximum Charge Current 25 A
Self-Discharge Rate Less than 2% per month at 25°C (77°F)
Internal Resistance 5.5 
Capacity
Cold Crank Amps (CCA) 0°F / -18°C 500
Marine Crank Amps (MCA) 32°F / 0°C 800
Reserve Capacity (RC @ 25A) 155 Minutes
Reserve Capacity (RC @ 75A) 34 Minutes
Capacity Affect by Temperature 40°C
(104°F)
25°C
(77°F)
0°C
(32°F)
-15°C
(5°F)
102% 100% 85% 65%
Hour Rate Capacity / AMP Hour Current / AMPs
@ 100 Hour Rate 95 AH 0.95 A
@ 20 Hour Rate 85 AH 4.25 A
@ 10 Hour Rate 77 AH 7.7 A
@ 5 Hour Rate 70 AH 14 A

7.7

Cut Off Voltage Constant Current Discharge
 VPC 1 hr 2 hr 3 hr 5 hr 8 hr 10 hr
43.8 25.6 19.2 13.9 9.2  
Series AGM-S Warranty See Warranty Terms
Volts 12 BCI Grp 24
Cells 6    
Terminal Type DT
Included Hardware Stainless Steel Nuts & Bolts
Size & Thread DT

Rolls - S12-95 AGM-RE Battery

Regular price $399.00

S12-95AGM-RE

Description
Charge
Charge Voltage Range 14.7V @ 25°C (77°F)
Float Voltage Range 13.8V @ 25°C (77°F)
Recommended Charge Current 15 A
Maximum Charge Current 25 A
Self-Discharge Rate Less than 2% per month at 25°C (77°F)
Internal Resistance 5.5 
Capacity
Cold Crank Amps (CCA) 0°F / -18°C 500
Marine Crank Amps (MCA) 32°F / 0°C 800
Reserve Capacity (RC @ 25A) 155 Minutes
Reserve Capacity (RC @ 75A) 34 Minutes
Capacity Affect by Temperature 40°C
(104°F)
25°C
(77°F)
0°C
(32°F)
-15°C
(5°F)
102% 100% 85% 65%
Hour Rate Capacity / AMP Hour Current / AMPs
@ 100 Hour Rate 95 AH 0.95 A
@ 20 Hour Rate 85 AH 4.25 A
@ 10 Hour Rate 77 AH 7.7 A
@ 5 Hour Rate 70 AH 14 A

7.7

Cut Off Voltage Constant Current Discharge
 VPC 1 hr 2 hr 3 hr 5 hr 8 hr 10 hr
43.8 25.6 19.2 13.9 9.2  
Series AGM-S Warranty See Warranty Terms
Volts 12 BCI Grp 24
Cells 6    
Terminal Type DT
Included Hardware Stainless Steel Nuts & Bolts
Size & Thread DT